We thinks what clients think, the urgency of urgency to act from the interests of a client position of theory, allowing for greater quality, lessen processing costs, price ranges are much more reasonable, won the new and outdated shoppers the support and affirmation for Digital Air Pressure Gauge, Level Transmitter, Small Digital Temperature Gauge, we could solve our customer problems asap and do the profit for our customer. If you need good service and quality , pls choose us , thanks !
Good Quality Flowmeter - MD-EL Electromagnetic Flowmeter – MEOKON Detail:

Application:

Clean water &sewage   Electricity production &distribution   Chemical & industrial pharmacy   Food industry

Technical characteristics:

1. No moving parts and no wear

2. The measurement range of the process is 1: 100

3. No clear section or flow enhancement device

4. Measuring the flow rate of various conductive liquids

5. Measurement results are not affected by physical properties such as temperature, pressure, viscosity, and density

6. Strong corrosion resistance and wear resistance

7. Measures forward / reverse flow

8. Large LCD screen, user-friendly operation interface, easy to use

9. Persistent EEPROM for saving configuration parameters and measurement data during power failure

10. Wide operation voltage range

11. Self-diagnosis

Technical Parameters:

Display LCD display, display various flow data in real-time, m³ or L display unit
Structure Embedded type design, integrated or split type
Measuring medium Liquid or solid-liquid, Conductivity> 0.5μs / cm2
Measuring Range 0.05m/s~8m/s
Measurement Accuracy Diameter  mm Range m/s Accuracy

3~20

0.3 or less ±0.25%FS
0.3~1 ±1.0%R
1~10 ±0.5%R

25~600

0.1~0.3 ±0.25%FS
0.3~1 ±0.5%R
1~10 ±0.3%R

700~3000

0.3 or less ±0.25%FS
0.3~1 ±1.0%R
1~10 ±0.5%R
%FS: relative range,  %R: relative measurement
Caliber(mm) 6mm~2000mm
Nominal pressure PN6, PN10, PN16, PN25, PN40, PN63, PN100, PN160, PN250, PN420 etc.
Output 4~20mA or frequency (<5KHz), RS485, wireless transmission (optional), relay (optional)
Connection DN6 ~ DN2000 for flange connection
Connection standard Applicable to various pipe flange standards
Product Standards Accuracy requirements meet JJG 1033-2007 standard
IP rating IP65(integrated), IP67 or IP68 when split (optional)
Power supply AC86~220V
Ambient temperature 5~55℃
Environment humidity <85%r.h(Non-condensing)

Product detail pictures:


Related Product Guide:

We generally continually give you quite possibly the most conscientious shopper company, and the widest variety of designs and styles with finest materials. These endeavours include the availability of customized designs with speed and dispatch for Good Quality Flowmeter - MD-EL Electromagnetic Flowmeter – MEOKON , The product will supply to all over the world, such as: British, Senegal, Eindhoven, Many years of work experience, we have now realized the importance of providing good quality products and solutions and the best before-sales and after-sales services. Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. faster delivery time and the product you want is our Criterion .
A good manufacturers, we have cooperated twice, good quality and good service attitude.
5 Stars By Cora from Egypt - 2018.02.21 12:14
The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
5 Stars By Irene from Nepal - 2018.07.26 16:51
Write your message here and send it to us