China Gold Supplier for Pressure Control Switch For Water Pump - Meokon manual pressure pump tester pressure gauge calibration table – MEOKON

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Reliable quality and good credit standing are our principles, which will help us at a top-ranking position. Adhering to the tenet of "quality first, customer supreme" for Rh Humidity Sensor, Water Pressure Transmitter, Electronic Digital Pressure Switch, We are able to customize the solutions according to your needs and we can easily pack it for you when you purchase.
China Gold Supplier for Pressure Control Switch For Water Pump - Meokon manual pressure pump tester pressure gauge calibration table – MEOKON Detail:

Shape Structure

NO. DESCRIPTION FUCTION
1 Standard table interface :For connecting a standard pressure gauge (thread size M20X1.5)
2 Knob of output shut-off valve:Connect the calibrated pressure instrument interface (thread size M20X1.5)
3 Reservoir cup:Store pressure measuring medium
4 Pressure relief valve knob:Loosen to release the pressure in the pump
5 Pressure test port:Connect to the test pressure instrument port (thread size M 2 0 X l. 5 )
6 Knob of output:shut-off valve Cut off the connection between [pressure test interface] and pressure making system
7 Add/Decrease handwheel:Add/subtract for precise adjustment of applied pressure
8 Auxiliary bracket:Buckle and the edge of the operating table to reinforce the check table stability

PHENOMENON REASONS PROCESSING METHOD
Do not press up when pressing the handle 1. The pressure relief valve knob is not tightened 1. Tighten the pressure relief valve
2. The sealing ring in the quick connector falls off 2. Reinstall or replace with a new seal
3. The globe valve is not open 3. Open the shut-off valve
Minor leak 1. The quick connector is not tightened 1. Tighten the threaded joints everywhere
2. The sealing ring is worn or aged 2. Replace with a new sealing ring
3. The knob of the pressure relief valve is not tightened 3. Tighten the pressure relief valve


Product detail pictures:

China Gold Supplier for Pressure Control Switch For Water Pump - Meokon manual pressure pump tester pressure gauge calibration table – MEOKON detail pictures


Related Product Guide:

With a complete scientific quality management system, good quality and good faith, we win good reputation and occupied this field for China Gold Supplier for Pressure Control Switch For Water Pump - Meokon manual pressure pump tester pressure gauge calibration table – MEOKON , The product will supply to all over the world, such as: Anguilla, France, Angola, Our company will continue to serve customers with best quality, competitive price and timely delivery & the best payment term! We sincerely welcome friends from all over the world to visit& cooperate with us and enlarge our business. If you are interested in our products, please do not hesitate to contact us, we will be happy to provide you with further information!
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Johnny from Latvia - 2017.08.28 16:02
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Ray from Hungary - 2018.09.08 17:09
    Write your message here and send it to us